Summary for Test 2022-08-15-13-1
Test performed: CTM 202-November 2011Project Information
| Project Identifiers | Project ID: 214336 DEA: 07302404 EFIS: 0713000488 |
|---|---|
| DIST-CO-RTE-PM | 07-VEN-101-37/40 |
| Award Date | 11/17/2020 |
| Closeout Date | 09/24/2024 |
| Work Description | PADRE JUAN REHAB |
| Location Description | VEN 101 |
| QA Service Level | 1 (Verified on 02/26/2021) |
Sample Information
| Sample Taken Date | 08/15/2022 | Sample Unique Key | 13 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/15/2022 | Sample type | Quality Assurance |
| A brief description of the sample | 3/4" Recycled Base | The quantity of what the sample constitutes | 150 Cy |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Kevin |
| Last name of sampler or witnessed by | Hopkins | Title of sampler | Plant Inspector |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Granite Construction Portable Jobsite Plant | |
| Transportation Laboratory (TL) Number | C081522A | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Granite Construction: On-site Recycled Base |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | LCB | The fabricator/manufacturer designation for the sample | |
| The plant number | A detailed description of where the material sample was collected | Conveyor Belt | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | fine | |
| The concrete mix design number | G3-22-LRCYB-297R | Lot number | |
| Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2022-08-15-13
DIME Test ID: 2022-08-15-13-1
Testing Lab: CT D07 - Plant Services, Unit 1841
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2022-08-30
Test Results
What size aggregate is being tested?: Fine Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Measured
Tester's full name: Kevin Hopkins
Date of test: 08/16/2022
| Sieve Size | Cumulative Mass Retained | Cumulative Percent Passing | ||||
|---|---|---|---|---|---|---|
| 516 grams | ||||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 159.0 grams | 69 % | |||||
| 256.0 grams | 50 % | |||||
| 327.0 grams | 37 % | |||||
| 384.0 grams | 26 % | |||||
| 425.0 grams | 18 % | |||||
| 455.0 grams | 12 % | |||||
| 516.0 grams | ||||||
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/30/2022 ✔