Summary for Test 2022-07-29-37-1
Test performed: ASTM D217-16Project Information
| Project Identifiers | Project ID: 215179 DEA: 010F4704 EFIS: 0116000011 |
|---|---|
| DIST-CO-RTE-PM | 01-HUM-299-30.7/37.7 |
| Award Date | 11/19/2020 |
| Closeout Date | 11/27/2023 |
| Work Description | PLACE HMA & RHMA-G & CONSTRUCT SOLDIER PILE WALL. |
| Location Description | HUMBOLDT COUNTY NEAR WILLOW CREEK AT VARIOUS LOCATIONS FROM 0.1 MILE EAST OF CEDAR CREEK ROAD TO 1.1 MILES WEST OF ROUTE 96 JUNCTION |
| QA Service Level | 1 (Verified on 09/15/2020) |
Sample Information
| Sample Taken Date | 07/29/2022 | Sample Unique Key | 37 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/08/2022 |
| Sample type | Department Acceptance | A brief description of the sample | PSE, Asphalt Rubber Binder |
| The quantity of what the sample constitutes | 1 can | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | R | Last name of sampler or witnessed by | Wernor |
| Title of sampler | Tester | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Valero Benicia | Transportation Laboratory (TL) Number | 972493 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | |
|---|---|---|---|
| Performance Grade | PG 64-16 | Lot number | |
| Sublot number | Asphalt Rubber Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2022-07-29-37
DIME Test ID: 2022-07-29-37-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Test Release Date: 2022-08-15
Test Results
Determination: Unworked Penetration
Input Type: Measured
Tester's full name: Karen Sawyer
Date of test: 08/15/2022
Unworked Penetration, Test 1: 35 0.1 mm
Unworked Penetration, Test 2: 36 0.1 mm
Unworked Penetration, Test 3: 37 0.1 mm
Unworked Penetration: 36 0.1 mm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/15/2022 ✔