Summary for Test 2022-07-11-76-2

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 993345
DEA: 022J4004
EFIS: 0221000074
DIST-CO-RTE-PM02-LAS-395-56.5/R61.1
Award Date02/02/2022
Closeout Date11/23/2022
Work DescriptionCOLD PLANE ASPHALT CONCRETE PAVEMENT AND PLACE HMA.
Location DescriptionLASSEN COUNTY NEAR JANESVILLE FROM 0.1 MILE NORTH OF SUNNYSIDE ROAD TO 0.1 MILE NORTH OF ROUTE 36
QA Service Level1 (Verified on 11/01/2021)

Sample Information

Sample Taken Date07/11/2022 Sample Unique Key76
Date that the sample was received by the laboratory/organization performing the testing07/14/2022 Sample typeDepartment Acceptance
A brief description of the sampleFine RAP The quantity of what the sample constitutesProduction Start-Up Evaluation
From where was the sample collectedManufacturer First name of sampler or witnessed byCGI
Last name of sampler or witnessed by. Title of samplerConsultant
Telephone number of sampler Laboratory sample identificationD79089B
Linked DIME Sample ID The fabricator/manufacturer/facility nameHat Creek Construction and Materials – Ward Lake Pit (Litchfield, CA)
Transportation Laboratory (TL) Number896424 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeReclaimed Asphalt Pavement RAP SourceWard Lake Plant
Aggregate Size3/8 inch Aggregate Source
RAP Stockpile Stockpile Size (tons)
Reclaimed Asphalt Pavement Mix NumberNot set

Test Details

DIME Sample ID: 2022-07-11-76
DIME Test ID: 2022-07-11-76-2
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2022-08-16

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Arthur Mills
Date of test: 07/18/2022
Test procedure used?: no data
Mass of HMA Sample prior to ignition: no data
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): 0.00 %
Moisture Content: no data
Temperature Compensation Factor: no data
Test Temperature: no data
Corrected Asphalt Binder Content: 6.15 %
General comments (publicly viewable) (Max 1000 characters): Uncorrected

Test was verified on 8/16/2022 ✔