Summary for Test 2022-07-16-24-2
Test performed: ASTM D36-14ε1Project Information
| Project Identifiers | Project ID: 213411 DEA: 030H10U4 EFIS: 0317000246 |
|---|---|
| DIST-CO-RTE-PM | 03-SAC-5-9.7/24.9 |
| Award Date | 05/01/2019 |
| Closeout Date | 02/22/2024 |
| Work Description | Not set |
| Location Description | Construction on state highway in Sacramento County in and near Sacramento from 1.1 miles south of Elk Grove Boulevard to American River Viaduct |
| QA Service Level | 1 (Verified on 07/19/2019) |
Sample Information
| Sample Taken Date | 07/16/2022 | Sample Unique Key | 24 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/29/2022 | Sample type | Department Acceptance |
| A brief description of the sample | 1/2" RHMA-O | The quantity of what the sample constitutes | 1 can |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Emilio |
| Last name of sampler or witnessed by | Chavez | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | 2022-07-16-21 | The fabricator/manufacturer/facility name | Teichert Perkins |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | |
|---|---|---|---|
| Performance Grade | PG 64-16 | Lot number | 2 |
| Sublot number | 18 | Asphalt Rubber Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2022-07-16-24
DIME Test ID: 2022-07-16-24-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Test Release Date: 2022-08-10
Test Results
ASTM Thermometer used?: C
Input Type: Measured
Tester's full name: Juan Gomez
Date of test: 08/10/2022
Softening Point Sample 1: 74 C
Softening Point Sample 2: 74 C
Bath Liquid: freshly boiled distilled water
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/10/2022 ✔