Summary for Test 2022-07-15-52-3

Test performed: AASHTO T315-20

Project Information

Project IdentifiersProject ID: 215367
DEA: 021J4904
EFIS: 0220000084
DIST-CO-RTE-PM02-TEH-32-14.0/20.0
Award Date02/02/2021
Closeout Date04/11/2024
Work DescriptionPLACE HOT MIX ASPHALT (TYPE A).
Location DescriptionTEHAMA COUNTY ABOUT 28 MILES EAST OF FOREST RANCH FROM 1.1 MILES EAST OF DEER CREEK BRIDGE NO. 08-0068 TO 0.4 MILE WEST OF SLATE CREEK BRIDGE NO. 08-0154
QA Service Level1 (Verified on 12/24/2020)

Sample Information

Sample Taken Date07/15/2022 Sample Unique Key52
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/27/2022
Sample typeDepartment Acceptance A brief description of the samplePG 58-22
The quantity of what the sample constitutes1 Can From where was the sample collectedSource
First name of sampler or witnessed by_ Last name of sampler or witnessed by_
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameAlbina Asphalt Transportation Laboratory (TL) Number876977
Inspector Lot Number from the Transportation Laboratory (TL) FormJMF Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 58-22
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierAlbina Asphalt - Klamath Falls Plant - Klamath Falls OR MultigradeNo
Multigrade Type Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2022-07-15-52
DIME Test ID: 2022-07-15-52-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2022-08-11

Test Results


Phase: PAV residue
Input Type: Measured
Tester's full name: Erika Gonzalez
Date of test: 08/03/2022
Test Plate Diameter: 8 mm
Test Gap: 2 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 1.00 %
Stress Amplitude: 44.402 kPa
Phase Angle (δ) (for the 10 cycles): 47.8 degree
Complex Modulus (G*) (for the 10 measurements): 4439.620 kPa
Test Temperature (Specimen 1): 22.0 C
(G*) x sin(δ)=: 3289 kPa
General comments (publicly viewable) (Max 1000 characters): PAV

Test was verified on 8/11/2022