Summary for Test 2022-08-01-25-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 215789 DEA: 10462104 EFIS: 1013000266 |
---|---|
DIST-CO-RTE-PM | 10-TUO-108-R18.9/38.8 |
Award Date | 08/02/2021 |
Closeout Date | 06/26/2023 |
Work Description | COLD PLANE, HMA, DRAINAGE REPLACEMENT, AND MODIFY TRAFFIC STATIONS. |
Location Description | TUOLUMNE COUNTY IN AND NEAR LONG BARN FROM 0.1 MILE WEST OF LONG BARN ROAD TO 2.3 MILES EAST OF COW CREEK ROAD |
QA Service Level | 1 (Verified on 06/04/2021) |
Sample Information
Sample Taken Date | 08/01/2022 | Sample Unique Key | 25 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/02/2022 |
Sample type | Quality Assurance | A brief description of the sample | 3/4 HMA |
The quantity of what the sample constitutes | 2 boxes | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Paul | Last name of sampler or witnessed by | Oei |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 22-H-108 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | George Reed - Table Mountain Plant | Transportation Laboratory (TL) Number | 034443 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | 4 |
Sublot number | 18 | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2022-08-01-25
DIME Test ID: 2022-08-01-25-1
Testing Lab: CT D10 - District 10 Materials Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-04-19
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Hans Camenzind
Date of test: 08/04/2022
Test procedure used?: no data
Mass of HMA Sample prior to ignition: no data
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): 0.62 %
Moisture Content: no data
Temperature Compensation Factor: no data
Test Temperature: no data
Corrected Asphalt Binder Content: 4.74 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/19/2023 ✔