Summary for Test 2022-07-24-4-1

Test performed: AASHTO T209-12

Project Information

Project IdentifiersProject ID: 993659
DEA: 021J4204
EFIS: 0220000076
DIST-CO-RTE-PM02-SHA-273-11.8/12.6
Award Date05/10/2022
Closeout Date10/06/2022
Work DescriptionCONSTRUCT HMA STRUCTURAL SHOULDER SECTIONS AND MODIFY SIGNAL SYSTEM.
Location DescriptionSHASTA COUNTY IN REDDING FROM CLEAR CREEK ROAD TO 0.4 MILE NORTH OF WESTWOOD AVENUE
QA Service Level1 (Verified on 04/05/2022)

Sample Information

Sample Taken Date07/24/2022 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/26/2022
Sample typeDepartment Acceptance A brief description of the sample2 bags of Combined RAP
The quantity of what the sample constitutesProduction Start-Up Evaluation From where was the sample collectedManufacturer
First name of sampler or witnessed byJ.D. Last name of sampler or witnessed byAtkinson
Title of sampler Telephone number of sampler
Laboratory sample identificationD79114B Linked DIME Sample ID2022-07-24-2, 2022-07-24-3
The fabricator/manufacturer/facility nameTullis – Northstate Asphalt (Redding, CA) Transportation Laboratory (TL) Number037275
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeReclaimed Asphalt Pavement RAP SourceNorthstate Asphalt
Aggregate Size1/2-inch Aggregate Source
RAP StockpileContinuous Stockpile Size (tons)
Reclaimed Asphalt Pavement Mix NumberNot set

Test Details

DIME Sample ID: 2022-07-24-4
DIME Test ID: 2022-07-24-4-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2022-08-04

Test Results


Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Colt Sweeny
Date of test: 08/02/2022
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7335.7 grams
Mass of oven-dry sample in air for Sample 1: 2544.7 grams
Mass of container filled with the sample and water for Sample 1: 8887.3 grams
Temperature of Water: 78 °F
Specific Gravity for Sample 1: 2.562
Theoretical maximum density at 25°C (77°F): 159.5 lb/ft^3
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/4/2022