Summary for Test 2022-07-26-25-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 214573
DEA: 073096U4
EFIS: 0719000091
DIST-CO-RTE-PM07-LA-210-R0.0/R9.7
Award Date04/03/2020
Closeout Date06/06/2024
Work DescriptionPLACE CONCRETE PAVEMENT, BARRIER, HMA, DRAINAGE, AND ELECTRICAL.
Location DescriptionLOS ANGELES COUNTY IN LOS ANGELES FROM INTERSTATE 5 TO WHEATLAND AVENUE UNDERCROSSING
QA Service Level1 (Verified on 06/05/2020)

Sample Information

Sample Taken Date07/26/2022 Sample Unique Key25
Date that the sample was received by the laboratory/organization performing the testing07/26/2022 Sample typeQuality Assurance
A brief description of the sample3/8" HMA type A The quantity of what the sample constitutes100 Tons
From where was the sample collectedManufacturer First name of sampler or witnessed byKevin
Last name of sampler or witnessed byHopkins Title of samplerPlant Inspector
Telephone number of sampler Laboratory sample identificationKH201A
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan Materials Sun Valley #2
Transportation Laboratory (TL) NumberC072622A Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0021
The fabricator's/manufacturer's product name for the sampleCT Dike Mix 63763-2 The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedHMA Hot Bins
Where the material sample would have been placed if not sampledRoadbed Primary Aggregate Nominal Size3/8 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2022-07-26-25
DIME Test ID: 2022-07-26-25-1
Testing Lab: CT D07 - Plant Services, Unit 1841
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2022-08-11

Test Results


What type of gradation is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Kevin Hopkins
Date of test: 07/26/2022
Cumulative Percent Passing
100 %
100 %
100 %
100 %
100 %
99 %
82 %
63 %
44 %
29 %
19 %
11 %
5 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/11/2022