Summary for Test 2022-07-21-38-1
Test performed: AASHTO T59-16Project Information
| Project Identifiers | Project ID: 993603 DEA: 051N7004 EFIS: 0521000081 |
|---|---|
| DIST-CO-RTE-PM | 05-SLO-166-16.0/21.0 |
| Award Date | 04/22/2022 |
| Closeout Date | 03/28/2023 |
| Work Description | PARTIAL DEPTH RECYCLING AND OVERLAY WITH RHMA (GAP GRADED). |
| Location Description | SAN LUIS OBISPO COUNTY ABOUT 8 MILES EAST OF SANTA MARIA FROM 0.5 MILE WEST OF HUASNA RIVER BRIDGE TO 1.9 MILES WEST OF CUYAMA RIVER BRIDGE. |
| QA Service Level | 1 (Verified on 03/28/2022) |
Sample Information
| Sample Taken Date | 07/21/2022 | Sample Unique Key | 38 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/26/2022 |
| Sample type | Department Acceptance | A brief description of the sample | EMULSION / LOAD 19 / 2ND BOTTLE DOES NOT CONSTITUTE SPLIT SAMPLE AND IS NOT TESTED |
| The quantity of what the sample constitutes | 1 OF 2 BOTTLES | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | SEE | Last name of sampler or witnessed by | TL101 |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | WESTERN EMULSIONS | Transportation Laboratory (TL) Number | C220721H |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphaltic Emulsion | Emulsion Grade | PASS-R |
|---|---|---|---|
| Lot Number | Not set | Sub Lot | Not set |
| Dilution Percentage Rate | Not set |
Test Details
DIME Sample ID: 2022-07-21-38
DIME Test ID: 2022-07-21-38-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T59-16: Standard Method of Test for Emulsified Asphalts (Emulsified Asphalt Residue Evap. (Sec. 7))
Test Release Date: 2022-07-27
Test Results
How many beakers will be used to conduct the test?: 2
Input Type: Measured
Tester's full name: Adam Herrera
Date of test: 07/27/2022
Beaker 1 Mass of beaker, rod, screen (if used), and residue: 456.6 g
Beaker 1 Tare mass of the beaker, rod, and screen (if used): 424.2 g
Beaker 2 Mass of beaker, rod, screen (if used), and residue: 457.8 g
Beaker 2 Tare mass of the beaker, rod, and screen (if used): 425.4 g
Beaker 1 Residue: 64.8 %
Beaker 2 Residue: 64.8 %
Percentage of residue: 65 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/27/2022 ✔