Summary for Test 2022-07-18-23-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 993344
DEA: 022J3804
EFIS: 0221000072
DIST-CO-RTE-PM02-SIS-3-R48.0/51.0
Award Date12/20/2021
Closeout Date07/27/2023
Work DescriptionHMA OVERLAY AND REPLACE AC SURFACING.
Location DescriptionSISKIYOU COUNTY IN AND NEAR YREKA FROM 0.1 MILE SOUTH OF JUNIPER DRIVE TO 0.3 MILE NORTH OF CALAMITY LANE
QA Service Level1 (Verified on 11/01/2021)

Sample Information

Sample Taken Date07/18/2022 Sample Unique Key23
Date that the sample was received by the laboratory/organization performing the testing07/19/2022 Sample typeDepartment Acceptance
A brief description of the sample1 box of Lime Treated 3/8-inch Type A HMA (eq. PG 64-28 M) with 24.0% RAP and virgin PG 58-34 M from Valero – Benecia The quantity of what the sample constitutes750 tons
From where was the sample collectedJob Site First name of sampler or witnessed byM.
Last name of sampler or witnessed byBirkland Title of samplerTET
Telephone number of sampler Laboratory sample identificationD79101
Linked DIME Sample ID The fabricator/manufacturer/facility nameTullis – Northstate Asphalt (Redding, CA)
Transportation Laboratory (TL) Number853091 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/8 inch Lot number
Sublot number HMA Mix NumberNot set
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2022-07-18-23
DIME Test ID: 2022-07-18-23-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2022-08-01

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Arthur Mills
Date of test: 07/25/2022
Test procedure used?: no data
Mass of HMA Sample prior to ignition: no data
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): 0.67 %
Moisture Content: no data
Temperature Compensation Factor: no data
Test Temperature: no data
Corrected Asphalt Binder Content: 5.79 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/1/2022 ✔