Summary for Test 2022-07-17-7-1

Test performed: CTM 524-March 2013

Project Information

Project IdentifiersProject ID: 214493
DEA: 07311704
EFIS: 0715000013
DIST-CO-RTE-PM07-LA-134-0.0/R13.3
Award Date04/16/2020
Closeout Date07/09/2024
Work DescriptionCONCRETE SLAB REPLACEMENT, HMA PAVING, ELECTRICAL AND LANDSCAPE WORK.
Location DescriptionLOS ANGELES COUNTY IN LOS ANGELES, BURBANK, GLENDALE AND PASADENA FROM ROUTE 101/134 SEPARATION TO JUNCTION OF ROUTE 210/710
QA Service Level1 (Verified on 04/15/2020)

Sample Information

Sample Taken Date07/17/2022 Sample Unique Key7
Date that the sample was received by the laboratory/organization performing the testing07/17/2022 Sample typeDepartment Acceptance
A brief description of the sampleISR-RSC Beams The quantity of what the sample constitutes130 CY
From where was the sample collectedJob Site First name of sampler or witnessed byArnold
Last name of sampler or witnessed byTruong Title of samplerMREA
Telephone number of sampler2138084582 Laboratory sample identification22-1802
Linked DIME Sample ID The fabricator/manufacturer/facility nameGL THROOP
Transportation Laboratory (TL) Number22-1802 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberNA
The truck number from where the sample was collected3 The batch plant ticket number from where the sample was collected3
Concrete batch plantGL Throop The fabricator/manufacturer designation for the sampleNA
A detailed description of where the material sample was collectedChute Where the material sample would have been placed if not sampledLN 2 WB 134
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2022-07-17-7
DIME Test ID: 2022-07-17-7-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2022-07-20

Test Results


Number of specimens: 3
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: No
Input Type: Measured
Tester's full name: Arnold Truong
Date of test: 07/20/2022
Identification number: 22-1802
Width of specimen: 6 inch
Width of specimen 2: 5.9375 inch
Width of specimen 3: 6 inch
Depth of specimen: 6 inch
Depth of specimen 2: 6 inch
Depth of specimen 3: 6.0625 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum load applied: 8369 lb
Maximum load applied 2: 7830 lb
Maximum load applied 3: 8101 lb
Curing history and apparent moisture condition of the specimen: Sand pit
If specimen was capped, ground or if leather shims were used: No
Defects in specimen, including numbers of beams discarded during test: 0
Age of specimen: 3 days
Age of specimen in hours: no data
Modulus of rupture: 730 psi
Modulus of rupture 2: 690 psi
Modulus of rupture 3: 690 psi
Modulus of rupture average: 700 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/20/2022 ✔