Summary for Test 2016-07-13-10-3
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 209918 DEA: 07274804 EFIS: 0700000516 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-18-0.2 |
| Award Date | 12/09/2014 |
| Closeout Date | 01/15/2018 |
| Work Description | REPLACE BRIDGE DECK AND RAILING, REPAIR BENT CAPS AND COLUMNS. |
| Location Description | LOS ANGELES COUNTY AT LLANO AT COUNTY LINE OVERHEAD |
| QA Service Level | 1 (Verified on 01/08/2015) |
Sample Information
| Sample Taken Date | 07/13/2016 | Sample Unique Key | 10 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/22/2016 | Sample type | Quality Assurance |
| A brief description of the sample | Double Barrel Zap Screwlok | The quantity of what the sample constitutes | 4 |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Sarah |
| Last name of sampler or witnessed by | Hartz | Title of sampler | Unknown |
| Telephone number of sampler | Unknown | Laboratory sample identification | Unknown |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | Barsplice Arceiormittal Nucor |
| Transportation Laboratory (TL) Number | C866879 | Inspector Lot Number from the Transportation Laboratory (TL) Form | N/A |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Service | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Manufacturer | Arcelormittal Nucor |
| Coupler Manufacturer | BarSplice | Intermediate Assembler or Fabricator | Unknown |
| Rebar Size | #5 | Coupler Model | Double Barrel Zap |
| Coating Standards | ASTM A775 | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Unknown | Rebar Hoop Fabricator | Unknown |
| Coupler Component Heat/Lot Number(s) | 5154 | Rebar Heat Number(s) | 1523113, PL1520843351 |
| Rebar Size 2 | NA | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2016-07-13-10
DIME Test ID: 2016-07-13-10-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2016-07-25
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 07/22/2016
UTM: 400KIP
Temperature: 72 F
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 3 | 3 | #5/16mm | 0.31 | 27140 | 87550 | Service Splice | Fred |
General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 7/25/2016 ✔