Summary for Test 2016-07-13-8-3
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 209918 DEA: 07274804 EFIS: 0700000516 |
---|---|
DIST-CO-RTE-PM | 07-LA-18-0.2 |
Award Date | 12/09/2014 |
Closeout Date | 01/15/2018 |
Work Description | REPLACE BRIDGE DECK AND RAILING, REPAIR BENT CAPS AND COLUMNS. |
Location Description | LOS ANGELES COUNTY AT LLANO AT COUNTY LINE OVERHEAD |
QA Service Level | 1 (Verified on 01/08/2015) |
Sample Information
Sample Taken Date | 07/13/2016 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/22/2016 |
Sample type | Quality Assurance | A brief description of the sample | Double Barrel Zap Screwlok |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Sarah | Last name of sampler or witnessed by | Hartz |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Barsplice Arceiormittal Nucor | Transportation Laboratory (TL) Number | C409475 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | N/A | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Service | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | Arcelormittal Nucor |
Coupler Manufacturer | BarSplice | Intermediate Assembler or Fabricator | Unknown |
Rebar Size | #4 | Coupler Model | Double Barrel Zap |
Coating Standards | ASTM A775 | Shape of Rebar | Straight |
Rebar Hoop Diameter | Unknown | Rebar Hoop Fabricator | Unknown |
Coupler Component Heat/Lot Number(s) | 5155 | Rebar Heat Number(s) | 1512769, PL1620040151 |
Rebar Size 2 | NA | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2016-07-13-8
DIME Test ID: 2016-07-13-8-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2016-07-25
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 07/22/2016
UTM: 75KIP
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 3 | 16 | #4/13mm | 0.2 | 17052 | 85260 | Service Splice | Fred |
General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
WARNING: No graph data imported from Instron machine.
Test was verified on 7/25/2016 ✔