Summary for Test 2016-06-29-5-1

Test performed: ASTM C39-17a

Project Information

Project IdentifiersProject ID: 208714
DEA: 08043514
EFIS: 0800000010
DIST-CO-RTE-PM08-SBD-58-R22.2/R31.1
Award Date12/30/2014
Closeout Date08/29/2018
Work DescriptionREALIGN AND WIDEN 2 TO 4 LANES EXPRESSWAY
Location DescriptionHINKLEY ROAD FROM 2.4 MILES WEST OF HIDDEN RIVER ROAD TO? 0.7 MILE EAST OF LENWOOD ROAD.
QA Service Level1 (Verified on 03/22/2013)

Sample Information

Sample Taken Date06/29/2016 Sample Unique Key5
Date that the sample was received by the laboratory/organization performing the testing07/05/2016 Sample typeQuality Control
A brief description of the sample6X12 LCB The quantity of what the sample constitutes2
From where was the sample collectedJob Site First name of sampler or witnessed byMIKE
Last name of sampler or witnessed byNUNEZ Title of samplerQC TECH TWINING
Telephone number of samplerUnknown Laboratory sample identification915-46
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameRobertsons Barstow
Transportation Laboratory (TL) Number062916-46 Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierSR 58 EXPRESSWAY AT HINKLEY RD Structure nameEB ON RAMP STA 1427 00
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberLB16 0048
The truck number from where the sample was collectedNP The batch plant ticket number from where the sample was collectedNP
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedSTA 1427 00 Where the material sample would have been placed if not sampledUnknown
From Lot No.Unknown Bag Lot No.Unknown

Test Details

DIME Sample ID: 2016-06-29-5
DIME Test ID: 2016-06-29-5-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2016-07-21

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Matthew Clayton
Date of test: 07/06/2016
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.02 in
Average diameter of cylinder 2: 6.02 in
Maximum load on cylinder 1: 24510 lb
Maximum load on cylinder 2: 24880 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: no data
Age of specimen: 7 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.46 in^2
Cross sectional area of cylinder 2: 28.46 in^2
Compressive strength (to nearest 10 psi): 870 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/21/2016 ✔