Summary for Test 2016-07-08-18-2

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 208714
DEA: 08043514
EFIS: 0800000010
DIST-CO-RTE-PM08-SBD-58-R22.2/R31.1
Award Date12/30/2014
Closeout Date08/29/2018
Work DescriptionREALIGN AND WIDEN 2 TO 4 LANES EXPRESSWAY
Location DescriptionHINKLEY ROAD FROM 2.4 MILES WEST OF HIDDEN RIVER ROAD TO? 0.7 MILE EAST OF LENWOOD ROAD.
QA Service Level1 (Verified on 03/22/2013)

Sample Information

Sample Taken Date07/08/2016 Sample Unique Key18
Date that the sample was received by the laboratory/organization performing the testing07/08/2016 Sample typeDepartment Acceptance
A brief description of the sampleClass 2 Aggregate Base The quantity of what the sample constitutesUnknown
From where was the sample collectedJob Site First name of sampler or witnessed byLarry
Last name of sampler or witnessed byFrancisco Title of samplerTE
Telephone number of samplerUnknown Laboratory sample identification6279B
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameRobertsons Barstow
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Unknown
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedSta 34 50 Camino Road
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1 inch
The concrete mix design number Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2016-07-08-18
DIME Test ID: 2016-07-08-18-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2019-08-22

Test Results


Number of tests: 1
Input Type: Calculated
Tester's full name: Jose Mendez
Date of test: 07/13/2016
Temperature correction: no data
Temperature of solution: no data
Clay reading (test 1): no data
Sand reading (test 1): no data
Sand equivalent (test 1): no data
Sand equivalent before temperature correction: no data
Sand equivalent after temperature correction: 78
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/22/2019 ✔