Summary for Test 2022-07-11-9-2

Test performed: ASTM D92-12b

Project Information

Project IdentifiersProject ID: 66669
DEA: JMF-DATA
EFIS: JMF-DATA
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for storing JMF sample data
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date07/11/2022 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/11/2022
Sample typeQuality Control A brief description of the sample3/4 inch RHMA-G PG 64-16
The quantity of what the sample constitutes24 Boxes From where was the sample collectedJob Site
First name of sampler or witnessed byJames Last name of sampler or witnessed byBrewster
Title of samplerNot set Telephone number of samplerNot set
Laboratory sample identificationNot set Linked DIME Sample IDNot set
The fabricator/manufacturer/facility nameSyar Industries - Lake Herman Transportation Laboratory (TL) NumberNot set
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeAsphalt Modifier Asphalt Modifier TypeTricor Refining
Asphalt Modifier Mix NumberNot set

Test Details

DIME Sample ID: 2022-07-11-9
DIME Test ID: 2022-07-11-9-2
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: ASTM D92-12b: Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester (Flash Point)
Test Release Date: 2022-07-11

Test Results


Unit system used?: SI Units
Ambient Barometric Pressure unit?: mm Hg
Input Type: Calculated
Tester's full name: James Brewster
Date of test: 07/11/2022
Corrected Flash Point: 2 C
General comments (publicly viewable) (Max 1000 characters): Submitted from JMF - James Brewster

Test was verified on 7/11/2022