Summary for Test 2022-06-08-47-1

Test performed: CTM 523-May 2020

Project Information

Project IdentifiersProject ID: 214573
DEA: 073096U4
EFIS: 0719000091
DIST-CO-RTE-PM07-LA-210-R0.0/R9.7
Award Date04/03/2020
Closeout Date06/06/2024
Work DescriptionPLACE CONCRETE PAVEMENT, BARRIER, HMA, DRAINAGE, AND ELECTRICAL.
Location DescriptionLOS ANGELES COUNTY IN LOS ANGELES FROM INTERSTATE 5 TO WHEATLAND AVENUE UNDERCROSSING
QA Service Level1 (Verified on 06/05/2020)

Sample Information

Sample Taken Date06/08/2022 Sample Unique Key47
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/09/2022
Sample typeDepartment Acceptance A brief description of the sampleJPCP
The quantity of what the sample constitutes1300 cu. yd. From where was the sample collectedJob Site
First name of sampler or witnessed byPhilip Last name of sampler or witnessed byMaquiran
Title of samplerMREA Telephone number of sampler2133581518
Laboratory sample identification22-1402 Linked DIME Sample ID
The fabricator/manufacturer/facility nameFlatiron Plant - Paxton off-Ramp Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numberJPCP-3215-06
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected81
Concrete batch plant The fabricator/manufacturer designation for the sampleFlatiron
A detailed description of where the material sample was collectedLoader Bucket at Flatiron Batch Plant Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2022-06-08-47
DIME Test ID: 2022-06-08-47-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 523-May 2020: Method of Test for Flexural Strength of Concrete
Test Release Date: 2022-07-08

Test Results


Number of specimens: 2
Unit system used?: US Units
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Is a beam dimensional correction factor used?: No
Input Type: Calculated
Tester's full name: Phillip Maquiran
Date of test: 07/06/2022
Identification number: 22-1402
Width of specimen: 6 inch
Width of specimen 2: 6.06 inch
Depth of specimen: 6.06 inch
Depth of specimen 2: 6.06 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Maximum load applied: 8616 lb
Maximum load applied 2: 8987 lb
Curing history and apparent moisture condition of the specimen: Bury in sand
If specimen was capped, ground or if leather shims were used: None
Defects in specimen: None
Age of specimen: 28 days
Age of specimen in hours: no data
Modulus of rupture: 740 psi
Modulus of rupture 2: 760 psi
Modulus of rupture average: 750 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/8/2022