Summary for Test 2016-07-11-11-1

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 210209
DEA: 023E7714
EFIS: 0215000046
DIST-CO-RTE-PM02-TRI-299-36.9/53.5
Award Date06/25/2015
Closeout Date01/17/2018
Work DescriptionHMA PAVING, ADA RAMPS, POLYESTER CONCRETE AND GUARDRAIL
Location DescriptionTRINITY COUNTY AT AND NEAR JUNCTION CITY AND WEAVERVILLE FROM NORTH FORK TRINITY RIVER BRIDGE TO 0.1 MILE EAST OF INDUSTRIAL ROAD
QA Service Level1 (Verified on 08/18/2015)

Sample Information

Sample Taken Date07/11/2016 Sample Unique Key11
Date that the sample was received by the laboratory/organization performing the testing07/14/2016 Sample typeQuality Assurance
A brief description of the sampleFlash Welded Rebar Hoops The quantity of what the sample constitutes4
From where was the sample collectedFabricator First name of sampler or witnessed byTory
Last name of sampler or witnessed byMclaurin Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameRKR Steel Welding
Transportation Laboratory (TL) NumberC705711 Inspector Lot Number from the Transportation Laboratory (TL) FormL6713616
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)65024141
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size5
Diameter of Hoop2'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerGerdau
Welding CompanyRKR Steel Welding Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2016-07-11-11
DIME Test ID: 2016-07-11-11-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2016-07-19

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 07/18/2016
UTM: 400KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
111#5/16mm0.313042098130Bar BrokeBrian

General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 7/19/2016 ✔