Summary for Test 2022-06-30-9-1
Test performed: CTM 231-March 2013Project Information
| Project Identifiers | Project ID: 214337 DEA: 080E33U4 EFIS: 0817000075 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-115-R7.3/R10.0 |
| Award Date | 04/26/2021 |
| Closeout Date | 06/09/2025 |
| Work Description | ADD WB AUX & EB DECEL LANES, WIDEN I15 SW CONNECT,RAMPS/BRDG |
| Location Description | SAN BERNARDINO COUNTY IN ONTARIO FROM 0.2 MILE WEST OF CUCAMONGA CREEK BRIDGE TO MILLIKEN AVENUE |
| QA Service Level | 1 (Verified on 06/23/2021) |
Sample Information
| Sample Taken Date | 06/30/2022 | Sample Unique Key | 9 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/30/2022 |
| Sample type | Quality Assurance | A brief description of the sample | Soil for structure backfill. |
| The quantity of what the sample constitutes | 442 SQF | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Julius | Last name of sampler or witnessed by | E |
| Title of sampler | TET | Telephone number of sampler | |
| Laboratory sample identification | 06302022-01 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | AT THE JOB SITE | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | OMAR G |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | AT THE JOBSITE | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2022-06-30-9
DIME Test ID: 2022-06-30-9-1
Testing Lab: CT D08 - Barstow Field Laboratory 1
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2022-07-01
Test Results
Method Type:: Standard Count
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Julius E
Date of test: 06/30/2022
Gage No.: 36636
Test No.: 1
Nuclear By: JULIUS E
Non-Bias Plan No.: 2
Depth: 8
Material No.: NATIVE
Material Type: SUBGRADE
Impact By: JULIUS E
Standard Count Density: 1822 g/cc
Count or Density 1: 1325 g/cc
Count or Density 2: 980 g/cc
Count or Density 3: 987 g/cc
Standard Count Moisture: 650 g/cc
Moisture Count 1: 97 g/cc
Moisture Count 2: 134 g/cc
Moisture Count 3: 116 g/cc
Sum of Count or Density: 3292 g/cc
Average of Count or Density: 1097 g/cc
Sum of Moisture Count: 347 g/cc
Average of Moisture Count: 116 g/cc
Count Ratio Density: 0.6
Count Ratio Moisture: 0.18
Calculated Percent Relative Compaction: 94.2 %
Reported Percent Relative Compaction: 94 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/1/2022 ✔
