Summary for Test 2022-06-16-35-3

Test performed: AASHTO T315-20

Project Information

Project IdentifiersProject ID: 993603
DEA: 051N7004
EFIS: 0521000081
DIST-CO-RTE-PM05-SLO-166-16.0/21.0
Award Date04/22/2022
Closeout Date03/28/2023
Work DescriptionPARTIAL DEPTH RECYCLING AND OVERLAY WITH RHMA (GAP GRADED).
Location DescriptionSAN LUIS OBISPO COUNTY ABOUT 8 MILES EAST OF SANTA MARIA FROM 0.5 MILE WEST OF HUASNA RIVER BRIDGE TO 1.9 MILES WEST OF CUYAMA RIVER BRIDGE.
QA Service Level1 (Verified on 03/28/2022)

Sample Information

Sample Taken Date06/16/2022 Sample Unique Key35
Date that the sample was received by the laboratory/organization performing the testing06/24/2022 Sample typeDepartment Acceptance
A brief description of the sampleRhma-g w/ LIME PG64-16 The quantity of what the sample constitutes1 Can
From where was the sample collectedSource First name of sampler or witnessed by_
Last name of sampler or witnessed byPapich Title of samplerQC
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameSierra Pacific Materials
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeYes
Multigrade TypePG 64-16 / PG 64-10 Asphalt Binder Mix NumberNot set
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2022-06-16-35
DIME Test ID: 2022-06-16-35-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2022-07-06

Test Results


Phase: PAV residue
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 06/30/2022
Test Plate Diameter: 8 mm
Test Gap: 2 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 1.00 %
Stress Amplitude: 71.030 kPa
Phase Angle (δ) (for the 10 cycles): 62.2 degree
Complex Modulus (G*) (for the 10 measurements): 7103.076 kPa
Test Temperature (Specimen 1): 28.0 C
(G*) x sin(δ)=: 6283 kPa
General comments (publicly viewable) (Max 1000 characters): pav

Test was verified on 7/6/2022 ✔