Summary for Test 2022-06-22-35-2

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 215789
DEA: 10462104
EFIS: 1013000266
DIST-CO-RTE-PM10-TUO-108-R18.9/38.8
Award Date08/02/2021
Closeout Date06/26/2023
Work DescriptionCOLD PLANE, HMA, DRAINAGE REPLACEMENT, AND MODIFY TRAFFIC STATIONS.
Location DescriptionTUOLUMNE COUNTY IN AND NEAR LONG BARN FROM 0.1 MILE WEST OF LONG BARN ROAD TO 2.3 MILES EAST OF COW CREEK ROAD
QA Service Level1 (Verified on 06/04/2021)

Sample Information

Sample Taken Date06/22/2022 Sample Unique Key35
Date that the sample was received by the laboratory/organization performing the testing06/22/2022 Sample typeQuality Assurance
A brief description of the sample1/2 HMA A The quantity of what the sample constitutes4 boxes
From where was the sample collectedManufacturer First name of sampler or witnessed byTim
Last name of sampler or witnessed byTrefz Title of samplerLab Technician
Telephone number of sampler Laboratory sample identification22-H-066
Linked DIME Sample ID2022-06-22-1 The fabricator/manufacturer/facility nameGRI, Table MTN
Transportation Laboratory (TL) Number723812 Inspector Lot Number from the Transportation Laboratory (TL) Form723812
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number1
Sublot number3 HMA Mix NumberNot set
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2022-06-22-35
DIME Test ID: 2022-06-22-35-2
Testing Lab: CT D10 - District 10 Materials Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-04-19

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Hans Camenzind
Date of test: 06/27/2022
Test procedure used?: no data
Mass of HMA Sample prior to ignition: no data
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): 0.45 %
Moisture Content: no data
Temperature Compensation Factor: no data
Test Temperature: no data
Corrected Asphalt Binder Content: 5.55 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/19/2023 ✔