Summary for Test 2022-06-22-10-5

Test performed: AASHTO T316-17

Project Information

Project IdentifiersProject ID: 993535
DEA: 081M1104
EFIS: 0821000078
DIST-CO-RTE-PM08-SBD-215-10.0/17.2
Award Date03/14/2022
Closeout Date12/05/2022
Work DescriptionHMA, COLD PLANE AC PAVEMENT, AND TRAFFIC STRIPE TAPE.
Location DescriptionSAN BERNARDINO COUNTY?FROM 0.1 MILE NORTH OF 27TH STREET TO 0.1 MILE SOUTH OF DEVORE ROAD
QA Service Level1 (Verified on 02/21/2022)

Sample Information

Sample Taken Date06/22/2022 Sample Unique Key10
Date that the sample was received by the laboratory/organization performing the testing06/21/2022 Sample typePer Request
A brief description of the samplePG Asphalt Binder The quantity of what the sample constitutes1 Quart Can
From where was the sample collectedSupplier First name of sampler or witnessed byIdris
Last name of sampler or witnessed byNajjar Title of sampler
Telephone number of sampler Laboratory sample identification0378-22
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan San Bernardino
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 58-34 M
ModifiedYes Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeNo
Multigrade Type Asphalt Binder Mix NumberNot set
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2022-06-22-10
DIME Test ID: 2022-06-22-10-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2022-06-28

Test Results


Is viscosity reading in cP/Pa-s?: Pa-s
Input Type: Calculated
Tester's full name: Sm Ali
Date of test: 06/22/2022
Time of test: 9:17 HH:MM
Test Temperature: 135.0 C
Speed: 50 rpm
Spindle size: 21 in
Torque: 84.0 %
Viscosity reading #1 (A) : 0.85 Pa-s
Viscosity reading #2 (B) : 0.84 Pa-s
Viscosity reading #3 (C): 0.839 Pa-s
Average viscosity: 0.843 Pa-s
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/28/2022