Summary for Test 2022-06-21-21-3

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 214451
DEA: 07303704
EFIS: 0714000035
DIST-CO-RTE-PM07-LA-101-8.0/27.3
Award Date12/19/2019
Closeout Date05/07/2024
Work DescriptionREPLACE CONCRETE BARRIERS.
Location DescriptionTHE CITY AND COUNTY OF LOS ANGELES FROM PILGRIMAGE OVERCROSSING TO VALLEY CIRCLE BOULEVARD OVERCROSSING
QA Service Level1 (Verified on 08/12/2020)

Sample Information

Sample Taken Date06/21/2022 Sample Unique Key21
Date that the sample was received by the laboratory/organization performing the testing06/27/2022 Sample typeDepartment Acceptance
A brief description of the sample3/4" HMA-A 105793 AAA Irwindale The quantity of what the sample constitutes750 Tons
From where was the sample collectedManufacturer First name of sampler or witnessed byGerardo
Last name of sampler or witnessed byZubieta Title of samplerTEC
Telephone number of sampler Laboratory sample identification22-0160
Linked DIME Sample ID The fabricator/manufacturer/facility nameAAA-Irwindale
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form924190A
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix NumberNot set
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2022-06-21-21
DIME Test ID: 2022-06-21-21-3
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2022-06-27

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Arnold Truong
Date of test: 06/27/2022
Test procedure used?: Method A
Mass of the specimen basket assembly: no data
Mass of the specimen and specimen basket assembly prior to ignition: no data
Mass of HMA Sample prior to ignition: 2053.4 g
Mass Loss: no data
Mass of aggregate remaining after ignition: 1955.4 g
Correction Factor (Percent by mass of HMA Specimen): 0.37 %
Moisture Content: 0.00 %
Temperature Compensation Factor: no data
Test Temperature: 1000.4 F
Corrected Asphalt Binder Content: 4.40 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/27/2022 ✔