Summary for Test 2022-06-20-21-2
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 993590 DEA: 101J2004 EFIS: 1018000147 |
---|---|
DIST-CO-RTE-PM | 10-SJ-26-8.0/17.8 |
Award Date | 04/12/2022 |
Closeout Date | 05/10/2023 |
Work Description | COLD PLANE AND HMA OVERLAY. |
Location Description | SAN JOAQUIN COUNTY AT AND NEAR LINDEN AT VARIOUS LOCATIONS FROM 0.7 MILE EAST OF GOGNA ROAD TO 1.3 MILES WEST OF SHELLEY ROAD |
QA Service Level | 1 (Verified on 03/01/2022) |
Sample Information
Sample Taken Date | 06/20/2022 | Sample Unique Key | 21 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/21/2022 |
Sample type | Quality Assurance | A brief description of the sample | 3/4 Type A HMA |
The quantity of what the sample constitutes | 4 boxes | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Tim | Last name of sampler or witnessed by | Trefz |
Title of sampler | Lab Technician | Telephone number of sampler | |
Laboratory sample identification | 22-H-61 | Linked DIME Sample ID | 2022-06-20-1 |
The fabricator/manufacturer/facility name | GRI, Clements plant | Transportation Laboratory (TL) Number | 723803 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | 1 |
Sublot number | 13 | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2022-06-20-21
DIME Test ID: 2022-06-20-21-2
Testing Lab: CT D10 - District 10 Materials Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-04-19
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Manpreet Singh
Date of test: 06/22/2022
Test procedure used?: no data
Mass of HMA Sample prior to ignition: no data
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): 0.55 %
Moisture Content: no data
Temperature Compensation Factor: no data
Test Temperature: no data
Corrected Asphalt Binder Content: 5.13 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/19/2023 ✔