Summary for Test 2016-06-03-20-1
Test performed: CTM 214-August 2010Project Information
Project Identifiers | Project ID: 208967 DEA: 110223U4 EFIS: 1112000102 |
---|---|
DIST-CO-RTE-PM | 11-SD-5,89-R29.1/R30.5 |
Award Date | 12/18/2014 |
Closeout Date | 02/04/2022 |
Work Description | REPLACE AND WIDEN BRIDGE, RECONSTRUCT RAMPS AND INTERSECTION. |
Location Description | SAN DIEGO COUNTY IN SAN DIEGO FROM 0.4 MILE SOUTH OF GENESEE AVENUE OVERCROSSING TO SORRENTO VIADUCT |
QA Service Level | 1 (Verified on 01/21/2015) |
Sample Information
Sample Taken Date | 06/03/2016 | Sample Unique Key | 20 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/06/2016 |
Sample type | Department Acceptance | A brief description of the sample | 3/8 PCC Aggregates |
The quantity of what the sample constitutes | 2 bags | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Saeb | Last name of sampler or witnessed by | Khatib |
Title of sampler | TET | Telephone number of sampler | Unknown |
Laboratory sample identification | 16CPCC-0241 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Vulcan Mission Valley | Transportation Laboratory (TL) Number | c604180 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-37-0035::CHULA VISTA |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | Stockpile |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | |
The concrete mix design number | Lot number | Not set | |
Sublot number | Not set | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2016-06-03-20
DIME Test ID: 2016-06-03-20-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: CTM 214-August 2010: Method of Test for Soundness of Aggregates by Use of Sodium Sulfate
Test Release Date: 2016-07-12
Test Results
What size aggregate is being tested?: Coarse Aggregate
Input Type: Calculated
Tester's full name: Benjamin Lenz
Date of test: 06/30/2016
Percentage Loss of material retained on 2 x 1 ½ in. sieve: 0.0 %
Percentage Loss of material retained on 1 ½ x 1 in. sieve: 0.0 %
Percentage Loss of material retained on 1 x ¾ in. sieve: 0.0 %
Percentage Loss of material retained on ¾ x ½ in. sieve: 0.0 %
Percentage Loss of material retained on ½ x ⅜ in. sieve: 0.0 %
Percentage Loss of material retained on ⅜ in. x #4 sieve: 0.0 %
Percentage Loss of material retained on 2 in. through 1 1/2 in. sieve: 0.0 %
Percentage Loss of material retained on 1 in. through 3/4 in. sieve: 0.0 %
Percentage Loss of material retained on 3/4 in. through #4 sieve: 0.0 %
Weighted Average Percent Loss of Coarse Aggregate: 1.5 %
Batch Soundness Loss of Coarse Aggregate (2 1/2 in maximum): 0.0 %
Batch Soundness Loss of Coarse Aggregate (1 1/2 in maximum): 0.0 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/12/2016 ✔