Summary for Test 2016-07-07-13-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 210277
DEA: 051F8904
EFIS: 0514000072
DIST-CO-RTE-PM05-MON-1-28.0/28.4
Award Date05/13/2015
Closeout Date02/01/2018
Work DescriptionCONSTRUCT VIADUCT.
Location DescriptionMONTEREY COUNTY NEAR LUCIA FROM 0.1 MILE SOUTH OF BIG CREEK BRIDGE TO 2.8 MILES SOUTH OF DOLAN CREEK BRIDGE
QA Service Level1 (Verified on 06/01/2015)

Sample Information

Sample Taken Date07/07/2016 Sample Unique Key13
Date that the sample was received by the laboratory/organization performing the testing07/11/2016 Sample typeQuality Assurance
A brief description of the sample Couplers The quantity of what the sample constitutes4
From where was the sample collectedJob Site First name of sampler or witnessed byAlex
Last name of sampler or witnessed byNaime Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameDayton
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerDayton Superior Intermediate Assembler or FabricatorUnknown
Rebar Size#9 Coupler ModelBar-Lock
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)492019 492018 492015 Rebar Heat Number(s)SE15103067
Rebar Size 2 NA Coupler Unique IDNot set

Test Details

DIME Sample ID: 2016-07-07-13
DIME Test ID: 2016-07-07-13-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2016-07-12

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 07/12/2016
UTM: 400KIP
Halo ID: Small
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12C03#9/29mm109762497624Service SpliceBrian

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 7/12/2016 ✔