Summary for Test 2022-06-15-31-1

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 993771
DEA: 07325204
EFIS: 0716000082
DIST-CO-RTE-PM07-LA-210-R36.7/R37.1
Award Date02/15/2022
Closeout Date01/29/2024
Work DescriptionSan Gabriel River Bridge - CM/GC Project - Hinge And Diaphragm Repairs
Location DescriptionLos Angeles County - LOS ANGELES COUNTY IN IRWINDALE FROM 0.2 MILE EAST OF 0.7 MILE WEST OF IRWINDALE AVENUE OVECROSSING
QA Service Level1 (Verified on 04/21/2022)

Sample Information

Sample Taken Date06/15/2022 Sample Unique Key31
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/16/2022
Sample typeDepartment Acceptance A brief description of the sample1x4 and WCS
The quantity of what the sample constitutes20 cy From where was the sample collectedManufacturer
First name of sampler or witnessed byVictor Last name of sampler or witnessed byPham
Title of sampler Telephone number of sampler7142139548
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameFWI 210 Batch Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0025
The fabricator's/manufacturer's product name for the sampleRSC CONCRETE MIX The fabricator/manufacturer designation for the sampleMix 3018B1
The plant number A detailed description of where the material sample was collectedStockpile @ Plant
Where the material sample would have been placed if not sampledShoulder Primary Aggregate Nominal Size1 inch
The concrete mix design numberFIW-3018B1 Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2022-06-15-31
DIME Test ID: 2022-06-15-31-1
Testing Lab: CT D07 - Plant Services
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2022-06-22

Test Results


What size aggregate is being tested?: 1 in. x No. 4 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Measured
Tester's full name: Victor Pham
Date of test: 06/16/2022
Sieve SizeCumulative Mass RetainedCumulative Percent Passing
10645 grams
0.0 grams100 %
320.0 grams97 %
2290.0 grams78 %
8315.0 grams22 %
9831.0 grams8 %
10465.0 grams2 %
10530.0 grams1 %
10645.0 grams
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/22/2022