Summary for Test 2016-06-30-7-2
Test performed: ASTM C39-17aProject Information
| Project Identifiers | Project ID: 210111 DEA: 031F4204 EFIS: 0300001119 |
|---|---|
| DIST-CO-RTE-PM | 03-BUT-99-40.5/40.8 |
| Award Date | 05/13/2015 |
| Closeout Date | 11/30/2017 |
| Work Description | WIDEN SHOULDER ON STRUCTURE. |
| Location Description | BUTTE COUNTY NEAR CHICO FROM 0.2 MILE SOUTH TO 0.1 MILE NORTH OF ROCK CREEK BRIDGE |
| QA Service Level | 1 (Verified on 01/02/2015) |
Sample Information
| Sample Taken Date | 06/30/2016 | Sample Unique Key | 7 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/01/2016 |
| Sample type | Quality Control | A brief description of the sample | 6x12 concrete cylinders |
| The quantity of what the sample constitutes | cylinders | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | unk | Last name of sampler or witnessed by | Unknown |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Unknown | Transportation Laboratory (TL) Number | 2 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Unknown |
| Structure name | Unknown | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | Unknown |
|---|---|---|---|
| The truck number from where the sample was collected | Unknown | The batch plant ticket number from where the sample was collected | Unknown |
| Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
| A detailed description of where the material sample was collected | Unknown | Where the material sample would have been placed if not sampled | Unknown |
| From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2016-06-30-7
DIME Test ID: 2016-06-30-7-2
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2016-07-07
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Bang
Date of test: 07/07/2016
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.03 in
Average diameter of cylinder 2: 5.99 in
Maximum load on cylinder 1: 100060 lb
Maximum load on cylinder 2: 94604 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: no data
Age of specimen: 7 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.56 in^2
Cross sectional area of cylinder 2: 28.18 in^2
Compressive strength of cylinder 1: 3503.5 psi
Compressive strength of cylinder 2: 3357.1 psi
Compressive strength (to nearest 10 psi): 3430 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for Cylinder Code 1 of 2
Source: Partner Data Point File
Test graph for Cylinder Code 2 of 2
Test was verified on 7/7/2016 ✔