Summary for Test 2022-05-27-22-3

Test performed: AASHTO T315-20

Project Information

Project IdentifiersProject ID: 215425
DEA: 06360244
EFIS: 0613000005
DIST-CO-RTE-PM06-TUL-99-30.6/35.2
Award Date04/26/2021
Closeout Date08/31/2026
Work DescriptionWiden Freeway & Bridge Construction (Concrete Bridge)
Location DescriptionNot set
QA Service Level1 (Verified on 11/01/2021)

Sample Information

Sample Taken Date05/27/2022 Sample Unique Key22
Date that the sample was received by the laboratory/organization performing the testing06/15/2022 Sample typeDepartment Acceptance
A brief description of the sample3/4-inch Type A HMA, PG 64-10 The quantity of what the sample constitutes1 Can
From where was the sample collectedOther First name of sampler or witnessed byEric
Last name of sampler or witnessed by_ Title of samplerQC
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameSan Joaquin Refining Co Inc
Transportation Laboratory (TL) Number772667 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-10
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeNo
Multigrade Type Asphalt Binder Mix NumberNot set
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2022-05-27-22
DIME Test ID: 2022-05-27-22-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-20: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2022-06-20

Test Results


Phase: PAV residue
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 06/16/2022
Test Plate Diameter: 8 mm
Test Gap: 2 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 1.00 %
Stress Amplitude: 65.484 kPa
Phase Angle (δ) (for the 10 cycles): 63.0 degree
Complex Modulus (G*) (for the 10 measurements): 6547.961 kPa
Test Temperature (Specimen 1): 31.0 C
(G*) x sin(δ)=: 5834 kPa
General comments (publicly viewable) (Max 1000 characters): PAV

Test was verified on 6/20/2022 ✔