Summary for Test 2022-02-16-34-3
Test performed: AASHTO T30-19Project Information
| Project Identifiers | Project ID: 993252 DEA: 030H6504 EFIS: 0316000003 |
|---|---|
| DIST-CO-RTE-PM | 03-COL-20-34.8/36.5 |
| Award Date | 11/17/2021 |
| Closeout Date | 07/21/2023 |
| Work Description | RDWY EXCAVATION, COLD PLANE AC PVMT, & OVERLAY. |
| Location Description | COLUSA COUNTY 1.7 MILES EAST OF COLUSA FROM NIAGARA AVENUE TO 0.3 MILE WEST OF STEIDLMAYER ROAD |
| QA Service Level | 1 (Verified on 09/27/2021) |
Sample Information
| Sample Taken Date | 02/16/2022 | Sample Unique Key | 34 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/22/2022 |
| Sample type | Verification | A brief description of the sample | 3/8" RAP |
| The quantity of what the sample constitutes | bags of Rap | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | M | Last name of sampler or witnessed by | Atterberry |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Teichert Hallwood | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Reclaimed Asphalt Pavement | RAP Source | Teichert Hallwood |
|---|---|---|---|
| Aggregate Size | Aggregate Source | ||
| RAP Stockpile | Stockpile Size (tons) | ||
| Reclaimed Asphalt Pavement Mix Number | Not set |
Test Details
DIME Sample ID: 2022-02-16-34
DIME Test ID: 2022-02-16-34-3
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Test Release Date: 2022-06-14
Test Results
Does this test use 1/4 sieve?: No
Is an aggregate correction factor used?: No
Input Type: Measured
Tester's full name: Julian Gonzales
Date of test: 02/22/2022
| Cumulative Mass Retained | Cumulative Percent Passing | |||||
|---|---|---|---|---|---|---|
| 1551.2 grams | ||||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 0.0 grams | 100 % | |||||
| 74.0 grams | 95.2 % | |||||
| 315.6 grams | 79.7 % | |||||
| 784.9 grams | 49.4 % | |||||
| 1066.5 grams | 31.2 % | |||||
| 1197.3 grams | 22.8 % | |||||
| 1272.8 grams | 17.9 % | |||||
| 1334.7 grams | 14 % | |||||
| 1390.9 grams | 10.3 % | |||||
| 1434.8 grams | 7.5 % | |||||
General comments (publicly viewable) (Max 1000 characters): JMF22-008
Test was verified on 6/14/2022 ✔