Summary for Test 2022-02-16-34-2
Test performed: AASHTO T209-12Project Information
Project Identifiers | Project ID: 993252 DEA: 030H6504 EFIS: 0316000003 |
---|---|
DIST-CO-RTE-PM | 03-COL-20-34.8/36.5 |
Award Date | 11/17/2021 |
Closeout Date | 07/21/2023 |
Work Description | RDWY EXCAVATION, COLD PLANE AC PVMT, & OVERLAY. |
Location Description | COLUSA COUNTY 1.7 MILES EAST OF COLUSA FROM NIAGARA AVENUE TO 0.3 MILE WEST OF STEIDLMAYER ROAD |
QA Service Level | 1 (Verified on 09/27/2021) |
Sample Information
Sample Taken Date | 02/16/2022 | Sample Unique Key | 34 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/22/2022 |
Sample type | Verification | A brief description of the sample | 3/8" RAP |
The quantity of what the sample constitutes | bags of Rap | From where was the sample collected | Supplier |
First name of sampler or witnessed by | M | Last name of sampler or witnessed by | Atterberry |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Teichert Hallwood | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Reclaimed Asphalt Pavement | RAP Source | Teichert Hallwood |
---|---|---|---|
Aggregate Size | Aggregate Source | ||
RAP Stockpile | Stockpile Size (tons) | ||
Reclaimed Asphalt Pavement Mix Number | Not set |
Test Details
DIME Sample ID: 2022-02-16-34
DIME Test ID: 2022-02-16-34-2
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2022-06-14
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Julian Gonzales
Date of test: 02/24/2022
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7345.5 grams
Mass of oven-dry sample in air for Sample 1: 1504.6 grams
Mass of container filled with the sample and water for Sample 1: 8269.9 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.593
Theoretical maximum density at 25°C (77°F): 161.4 lb/ft^3
General comments (publicly viewable) (Max 1000 characters): JMF22-008
Test was verified on 6/14/2022 ✔