Summary for Test 2022-06-13-8-2

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 215220
DEA: 07210624
EFIS: 0719000068
DIST-CO-RTE-PM07-LA,SBD-71-1.8/R4.7&R0.0/R0.2
Award Date02/05/2021
Closeout DateNot set
Work DescriptionPLACE STRUCTURE CONCRETE RETAINING WALLS & BOX CULVERT AND PLACE JPCP.
Location DescriptionIN LOS ANGELES AND SAN BERNARDINO COUNTIES IN POMONA AND CHINO HILLS FROM 0.2 MILE SOUTH OF MISSION BOULEVARD OVERCROSSING TO 0.2 MILE OF SAN BERNARDINO COUNTY LINE.
QA Service Level1 (Verified on 03/24/2021)

Sample Information

Sample Taken Date06/13/2022 Sample Unique Key8
Date that the sample was received by the laboratory/organization performing the testing06/13/2022 Sample typeDepartment Acceptance
A brief description of the sampleWashed Concrete Sand The quantity of what the sample constitutes60 CY
From where was the sample collectedManufacturer First name of sampler or witnessed byHonesto
Last name of sampler or witnessed byCastillo Title of samplerMREAS
Telephone number of sampler12134537563 Laboratory sample identification30B
Linked DIME Sample ID The fabricator/manufacturer/facility nameRobertson Ready Mix Concrete-Pomona
Transportation Laboratory (TL) NumberC-006599 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-36-0072
The fabricator's/manufacturer's product name for the samplePCC mix The fabricator/manufacturer designation for the sampleMix RRM17066
The plant number5 A detailed description of where the material sample was collectedBelt Cut at Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Sizefine
The concrete mix design numberRRM17066 Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2022-06-13-8
DIME Test ID: 2022-06-13-8-2
Testing Lab: CT D07 - Plant Services, Unit 1841
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2022-06-16

Test Results


Number of tests: 2
Input Type: Measured
Tester's full name: Honesto Castillo
Date of test: 06/13/2022
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 5
Sand reading (test 1): 3.9
Clay reading (test 2): 5.1
Sand reading (test 2): 3.9
Sand equivalent (test 1): 78
Sand equivalent (test 2): 77
Sand equivalent before temperature correction: 78
Sand equivalent after temperature correction: 78
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/16/2022 ✔