Summary for Test 2022-06-11-3-1
Test performed: CTM 231-March 2013Project Information
| Project Identifiers | Project ID: 993771 DEA: 07325204 EFIS: 0716000082 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-210-R36.7/R37.1 |
| Award Date | 02/15/2022 |
| Closeout Date | 01/29/2024 |
| Work Description | San Gabriel River Bridge - CM/GC Project - Hinge And Diaphragm Repairs |
| Location Description | Los Angeles County - LOS ANGELES COUNTY IN IRWINDALE FROM 0.2 MILE EAST OF 0.7 MILE WEST OF IRWINDALE AVENUE OVECROSSING |
| QA Service Level | 1 (Verified on 04/21/2022) |
Sample Information
| Sample Taken Date | 06/11/2022 | Sample Unique Key | 3 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/11/2022 |
| Sample type | Department Acceptance | A brief description of the sample | Aggregate Base |
| The quantity of what the sample constitutes | 9550 SF | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Michelangelo | Last name of sampler or witnessed by | Sese |
| Title of sampler | TET | Telephone number of sampler | 310-345-6204 |
| Laboratory sample identification | 22-1424 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | NA | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Aggregate Base |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | Various locations | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2022-06-11-3
DIME Test ID: 2022-06-11-3-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2022-06-12
Test Results
Method Type:: Direct Read
Number of Tests:: 5
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Michelangelo Sese
Date of test: 06/11/2022
Gage No.: 63091
Test No.: no data
Nuclear By: Michelangelo Sese
Non-Bias Plan No.: 4
Depth: 4
Material No.: no data
Material Type: Aggregate Base
Impact By: Michelangelo Sese
Standard Count Density: 1615 g/cc
Count or Density 1: 2 g/cc
Count or Density 2: 1.96 g/cc
Count or Density 3: 2.17 g/cc
Count or Density 4: 2.06 g/cc
Count or Density 5: 2.1 g/cc
Standard Count Moisture: 645 g/cc
Moisture Count 1: 0.22 g/cc
Moisture Count 2: 0.19 g/cc
Moisture Count 3: 0.27 g/cc
Moisture Count 4: 0.25 g/cc
Moisture Count 5: 0.24 g/cc
Sum of Count or Density: 10.29 g/cc
Average of Count or Density: 2.06 g/cc
Sum of Moisture Count: 1.17 g/cc
Average of Moisture Count: 0.23 g/cc
Calculated Percent Relative Compaction: 94 %
Reported Percent Relative Compaction: 94 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/12/2022 ✔