Summary for Test 2022-03-18-58-7
Test performed: AASHTO T324-14Project Information
Project Identifiers | Project ID: 66669 DEA: JMF-DATA EFIS: JMF-DATA |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for storing JMF sample data |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 03/18/2022 | Sample Unique Key | 58 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | Not set |
Sample type | Verification | A brief description of the sample | 16 boxes of Treated 1/2-inch Type A HMA (eq. PG 64-28 M) with 25.0% RAP and virgin PG 58-34 M binder from Valero Benicia |
The quantity of what the sample constitutes | JMF Verification | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Ward | Last name of sampler or witnessed by | Jenkins |
Title of sampler | Not set | Telephone number of sampler | Not set |
Laboratory sample identification | Not set | Linked DIME Sample ID | Not set |
The fabricator/manufacturer/facility name | Tullis - Northstate Asphalt - Redding, CA | Transportation Laboratory (TL) Number | Not set |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | Not set |
Sublot number | Not set | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2022-03-18-58
DIME Test ID: 2022-03-18-58-7
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Test Release Date: 2022-06-20
Test Results
Input Type: Calculated
Tester's full name: Karen Rios Dorado
Date of test: 04/03/2022
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth average: no data
Impression at specified number of passes average: no data
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A): 15000
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B): 15000
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A): 1.7 mm
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B): 1.46 mm
Stripping Inflection Point (Wheel A): >15000
Stripping Inflection Point (Wheel B): >15000
General comments (publicly viewable) (Max 1000 characters): Submitted from JMF - Ward Jenkins
Test was verified on 6/20/2022 ✔