Summary for Test 2022-06-07-19-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 215257
DEA: 11056374
EFIS: 1117000087
DIST-CO-RTE-PM11-SD-11-0.6/2.7
Award Date02/16/2021
Closeout DateNot set
Work DescriptionCONSTRUCT INTERCHANGE, PLACE JPCP, HMA, AND INSTALL LIGHTING.
Location DescriptionSAN DIEGO COUNTY NEAR SAN DIEGO FROM 0.2 MILE WEST OF SANYO AVENUE UNDERCROSSING TO 1.2 MILE EAST OF ENRICO FERMI DRIVE OVERCROSSING
QA Service Level1 (Verified on 11/25/2020)

Sample Information

Sample Taken Date06/07/2022 Sample Unique Key19
Date that the sample was received by the laboratory/organization performing the testing06/07/2022 Sample typeQuality Assurance
A brief description of the sample1/2" RHMA-G The quantity of what the sample constitutes2 bags, 12 boxes
From where was the sample collectedSource First name of sampler or witnessed byDavid
Last name of sampler or witnessed byWalker Title of sampler
Telephone number of sampler8582480978 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCCA Lakeside
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading1/2 inch Lot number
Sublot number HMA Mix NumberNot set
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2022-06-07-19
DIME Test ID: 2022-06-07-19-1
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-08-29

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 06/09/2022
Test procedure used?: Method A
Mass of the specimen basket assembly: no data
Mass of the specimen and specimen basket assembly prior to ignition: no data
Mass of HMA Sample prior to ignition: 1546.5 g
Mass Loss: no data
Mass of aggregate remaining after ignition: 1422.4 g
Correction Factor (Percent by mass of HMA Specimen): 0.20 %
Moisture Content: 0.00 %
Temperature Compensation Factor: no data
Test Temperature: 538 F
Corrected Asphalt Binder Content: 7.82 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/29/2024 ✔