Summary for Test 2022-05-10-40-1
Test performed: CTM 523-May 2020Project Information
| Project Identifiers | Project ID: 211260 DEA: 072159U4 EFIS: 0715000160 |
|---|---|
| DIST-CO-RTE-PM | 07-LA,ORA-5-0.0/1.5, 44.3/44.4 |
| Award Date | 05/27/2016 |
| Closeout Date | 08/01/2023 |
| Work Description | CONSTRUCT HOV LANES AND MIX FLOW LANES. |
| Location Description | LOS ANGELES AND ORANGE COUNTIES IN BUENA PARK, LA MIRADA, CERRITOS AND SANTA FE SPRINGS FROM ARTESIA BOULEVARD UNDERCROSSING TO NORTH FORK COYOTE CREEK |
| QA Service Level | 1 (Verified on 03/16/2016) |
Sample Information
| Sample Taken Date | 05/10/2022 | Sample Unique Key | 40 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 05/10/2022 | Sample type | Department Acceptance |
| A brief description of the sample | JPCP | The quantity of what the sample constitutes | 10cuyd |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Chad |
| Last name of sampler or witnessed by | Chotibhongs | Title of sampler | MREA |
| Telephone number of sampler | 213-817-0387 | Laboratory sample identification | 22-1092 |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Flatiron Plant - Paxton off-Ramp | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | G3-19-PCC-001 |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | Load 5 | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | Discharge from concrete truck into wheelbarrow. | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2022-05-10-40
DIME Test ID: 2022-05-10-40-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 523-May 2020: Method of Test for Flexural Strength of Concrete
Test Release Date: 2022-06-09
Test Results
Number of specimens: 2
Unit system used?: US Units
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Is a beam dimensional correction factor used?: No
Input Type: Measured
Tester's full name: Chad Chotibhongs
Date of test: 06/07/2022
Identification number: 22-1092
Width of specimen: 6.1 inch
Width of specimen 2: 6.0 inch
Depth of specimen: 6.0 inch
Depth of specimen 2: 6.1 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Maximum load applied: 8610 lb
Maximum load applied 2: 8670 lb
Curing history and apparent moisture condition of the specimen: 0
If specimen was capped, ground or if leather shims were used: 0
Defects in specimen: 0
Age of specimen: 28 days
Age of specimen in hours: no data
Modulus of rupture: 750 psi
Modulus of rupture 2: 740 psi
Modulus of rupture average: 750 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/9/2022 ✔