Summary for Test 2022-05-31-17-1
Test performed: ASTM D2196-Feb15Project Information
| Project Identifiers | Project ID: 993271 DEA: 11430604 EFIS: 1119000026 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-8,805-5.6/17.4 |
| Award Date | 11/16/2021 |
| Closeout Date | Not set |
| Work Description | INSTALL HIGH FRICTION SURFACE TREATMENT |
| Location Description | FOR CONSTRUCTION ON STATE HIGHWAY IN SAN DIEGO COUNTY IN SAN DIEGO ON ROUTE 8 AT ROUTE 15/8 SEPARATION AND ON ROUTE 805 AT NORTHBOUND 805 TO EASTBOUND 8 CONNECTOR |
| QA Service Level | 1 (Verified on 04/08/2022) |
Sample Information
| Sample Taken Date | 05/31/2022 | Sample Unique Key | 17 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/01/2022 | Sample type | Quality Assurance |
| A brief description of the sample | 1 gallon can | The quantity of what the sample constitutes | 2 Tankers |
| From where was the sample collected | Source | First name of sampler or witnessed by | Gilberto |
| Last name of sampler or witnessed by | Gonzalez | Title of sampler | Quality Control Manager |
| Telephone number of sampler | 7076245467 | Laboratory sample identification | 943113 |
| Linked DIME Sample ID | 943113 | The fabricator/manufacturer/facility name | Kwik Bond Polymers, Benicia |
| Transportation Laboratory (TL) Number | Sacramento Caltrans lab | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | High Friction Surface Treatment | Mgf. Lot Number(s) | 1408521 |
|---|---|---|---|
| Batch Number | 1408521 | Mix Number | 1408521 |
| Resin Binder Type | Polyester | Used for Overlay | Yes |
| Used for Inlay | No |
Test Details
DIME Sample ID: 2022-05-31-17
DIME Test ID: 2022-05-31-17-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational Viscometer
Test Release Date: 2022-06-09
Test Results
Input Type: Calculated
Tester's full name: Richard Wilmshurst
Date of test: 06/07/2022
Viscosity: 2044
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/9/2022 ✔