Summary for Test 2022-05-17-38-2
Test performed: AASHTO T59-16
Warning: The test results shown on this page have been superseded and are invalid.
This information is for reference only.
Please click this
link
to view the corrected test.
Project Information
| Project Identifiers | Project ID: 993471 DEA: 061C4604 EFIS: 0621000168 |
|---|---|
| DIST-CO-RTE-PM | 06-KER-223-R10.6/R20.1 |
| Award Date | 02/10/2022 |
| Closeout Date | 07/29/2022 |
| Work Description | RESURFACE WITH HMA (TYPE A) AND POLYMER ASPHALT EMULSION SEAL COAT. |
| Location Description | KERN COUNTY NEAR ARVIN FROM ROUTE 223/99 SEPARATION TO COMANCHE DRIVE |
| QA Service Level | 1 (Verified on 01/03/2022) |
Sample Information
| Sample Taken Date | 05/17/2022 | Sample Unique Key | 38 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 05/25/2022 | Sample type | Department Acceptance |
| A brief description of the sample | EMULSION | The quantity of what the sample constitutes | 1 OF 1 BOTTLES |
| From where was the sample collected | Other | First name of sampler or witnessed by | TALLY |
| Last name of sampler or witnessed by | OIL INC | Title of sampler | QC |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | TALLY OIL INC | |
| Transportation Laboratory (TL) Number | C771803 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphaltic Emulsion | Emulsion Grade | PMCRS-2h |
|---|---|---|---|
| Lot Number | Not set | Sub Lot | Not set |
| Dilution Percentage Rate | Not set |
Test Details
DIME Sample ID: 2022-05-17-38
DIME Test ID: 2022-05-17-38-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T59-16: Standard Method of Test for Emulsified Asphalts (Emulsified Asphalt Residue Evap. (Sec. 7))
Test Release Date: 2022-06-03
Test Results
How many beakers will be used to conduct the test?: 2
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 06/03/2022
Beaker 1 Mass of beaker, rod, screen (if used), and residue: 431.2 g
Beaker 1 Tare mass of the beaker, rod, and screen (if used): 417.4 g
Beaker 2 Mass of beaker, rod, screen (if used), and residue: 437.0 g
Beaker 2 Tare mass of the beaker, rod, and screen (if used): 423.3 g
Beaker 1 Residue: 27.6 %
Beaker 2 Residue: 27.4 %
Percentage of residue: 28 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/3/2022 ✔
Warning: The test results shown on this page have been superseded and are invalid.
This information is for reference only.