Summary for Test 2022-05-22-1-1

Test performed: CTM 389-19

Project Information

Project IdentifiersProject ID: 993234
DEA: 051H0004
EFIS: 0516000011
DIST-CO-RTE-PM05-MON-68-1.1/L4.3
Award Date10/26/2021
Closeout Date12/14/2023
Work DescriptionPLACE HMA AND MODIFY SIGNAL AND LIGHTING SYSTEMS.
Location DescriptionMONTEREY COUNTY IN AND NEAR PACIFIC GROVE AND MONTEREY FROM FOREST AVENUE TO ROUTE 68/1 SEPARATION
QA Service Level1 (Verified on 10/06/2021)

Sample Information

Sample Taken Date05/22/2022 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/22/2022
Sample typeDepartment Acceptance A brief description of the sample3/4" HMA Type A
The quantity of what the sample constitutes20 Box's HMA-A From where was the sample collectedFabricator
First name of sampler or witnessed byJerrod Last name of sampler or witnessed byNaval
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameGraniterock Aromas Drum Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number1
Sublot number18 HMA Mix NumberNot set
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2022-05-22-1
DIME Test ID: 2022-05-22-1-1
Testing Lab: CT D05 - San Luis Obispo District Laboratory
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Test Release Date: 2022-06-02

Test Results


Specified number of passes at 12.7 mm: 15000
Specimen Preparation Method:
Input Type: Measured
Tester's full name: Eric Atkins
Date of test: 06/02/2022
Test Temperature: 50 F
Compaction Method: SGC Cylindrical Specimen
Air Void Content for specimen A-1: no data
Air Void Content for specimen A-2: no data
Air Void Content for specimen B-1: no data
Air Void Content for specimen B-2: no data
Stripping Inflection Point (Wheel A): 9000
Stripping Inflection Point (Wheel B): >15000
Maximum impression at 5000 passes (left wheel): 2.09 mm
Maximum impression at 5000 passes (right wheel): 1.95 mm
Average impression at 5000 passes (left/right avg): 2.02 mm
Maximum impression at 10000 passes (left wheel): 3.44 mm
Maximum impression at 10000 passes (right wheel): 2.41 mm
Average impression at 10000 passes (left/right avg): 2.93 mm
Maximum impression at 15000 passes (left wheel): 6.43 mm
Maximum impression at 15000 passes (right wheel): 2.76 mm
Average impression at 15000 passes (left/right avg): 4.59 mm
Maximum impression at 20000 passes (left wheel): no data
Maximum impression at 20000 passes (right wheel): no data
Average impression at 20000 passes (left/right avg): no data
Maximum impression at 25000 passes (left wheel): no data
Maximum impression at 25000 passes (right wheel): no data
Average impression at 25000 passes (left/right avg): no data
Raw Data: no data
General comments (publicly viewable) (Max 1000 characters): 10K Milestone Sample ( 8 Box's of HMA-A for CTM 389, T275 and T269 )

Test was verified on 6/2/2022