Summary for Test 2016-06-13-8-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 209918
DEA: 07274804
EFIS: 0700000516
DIST-CO-RTE-PM07-LA-18-0.2
Award Date12/09/2014
Closeout Date01/15/2018
Work DescriptionREPLACE BRIDGE DECK AND RAILING, REPAIR BENT CAPS AND COLUMNS.
Location DescriptionLOS ANGELES COUNTY AT LLANO AT COUNTY LINE OVERHEAD
QA Service Level1 (Verified on 01/08/2015)

Sample Information

Sample Taken Date06/13/2016 Sample Unique Key8
Date that the sample was received by the laboratory/organization performing the testing06/23/2016 Sample typeQuality Assurance
A brief description of the sampleDouble Barrel Zap Screwlok The quantity of what the sample constitutes4
From where was the sample collectedJob Site First name of sampler or witnessed byS
Last name of sampler or witnessed byHartz Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameBarsplice Integrity Rebar
Transportation Laboratory (TL) NumberC409455 Inspector Lot Number from the Transportation Laboratory (TL) FormNA
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerIntegrity Rebar
Coupler ManufacturerBarsplice Intermediate Assembler or FabricatorUnknown
Rebar Size#4 Coupler ModelDouble Barrel Zap ScrewLok
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)5155 Rebar Heat Number(s)1512769
Rebar Size 2 NA Coupler Unique IDNot set

Test Details

DIME Sample ID: 2016-06-13-8
DIME Test ID: 2016-06-13-8-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2016-06-27

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 06/27/2016
UTM: 400KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12NA#4/13mm0.21601080050Service SpliceFred

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 6/27/2016 ✔