Summary for Test 2022-05-16-3-2

Test performed: AASHTO T269-14

Project Information

Project IdentifiersProject ID: 993234
DEA: 051H0004
EFIS: 0516000011
DIST-CO-RTE-PM05-MON-68-1.1/L4.3
Award Date10/26/2021
Closeout Date12/14/2023
Work DescriptionPLACE HMA AND MODIFY SIGNAL AND LIGHTING SYSTEMS.
Location DescriptionMONTEREY COUNTY IN AND NEAR PACIFIC GROVE AND MONTEREY FROM FOREST AVENUE TO ROUTE 68/1 SEPARATION
QA Service Level1 (Verified on 10/06/2021)

Sample Information

Sample Taken Date05/16/2022 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/16/2022
Sample typeDepartment Acceptance A brief description of the sample3/4" HMA Type A
The quantity of what the sample constitutes8 Box's HMA-A From where was the sample collectedFabricator
First name of sampler or witnessed byJerrod Last name of sampler or witnessed byNaval
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameGraniterock Aromas Drum Plant Transportation Laboratory (TL) Number956422
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number1
Sublot number8 HMA Mix NumberNot set

Test Details

DIME Sample ID: 2022-05-16-3
DIME Test ID: 2022-05-16-3-2
Testing Lab: CT D05 - San Luis Obispo District Laboratory
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Test Release Date: 2022-05-20

Test Results


Number of tests: 3
Input Type: Measured
Tester's full name: Eric Atkins
Date of test: 05/20/2022
123
2.497 2.492 2.495
2.574

3.0 %

3.2 %

3.1 %

3.1 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/20/2022