Summary for Test 2022-04-26-51-2
Test performed: ASTM D217-16Project Information
| Project Identifiers | Project ID: 215150 DEA: 120P0304 EFIS: 1215000024 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-74-11.5/16.6 |
| Award Date | 11/13/2020 |
| Closeout Date | 01/28/2025 |
| Work Description | PLACE HIGH FRICTION SURFACE TREATMENT, HMA & MIDWEST GUARDRAIL SYSTEM. |
| Location Description | ORANGE COUNTY NEAR SAN JUAN CAPISTRANO FROM 1.0 MILE WEST OF SAN JUAN HOT SPRINGS ROAD TO ORANGE COUNTY LINE |
| QA Service Level | 1 (Verified on 12/10/2020) |
Sample Information
| Sample Taken Date | 04/26/2022 | Sample Unique Key | 51 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/16/2022 |
| Sample type | Verification | A brief description of the sample | Asphalt Rubber Binder |
| The quantity of what the sample constitutes | 1 Quart Can | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | RJ Noble QC RJ | Last name of sampler or witnessed by | QC |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 0289-22 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | RJ Noble-Orange | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | |
|---|---|---|---|
| Performance Grade | PG 64-16 | Lot number | |
| Sublot number | Asphalt Rubber Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2022-04-26-51
DIME Test ID: 2022-04-26-51-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Test Release Date: 2022-06-06
Test Results
Determination: Unworked Penetration
Input Type: Calculated
Tester's full name: Majid Essa
Date of test: 05/19/2022
Unworked Penetration: 54 0.1 mm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/6/2022 ✔