Summary for Test 2022-05-19-22-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 993234 DEA: 051H0004 EFIS: 0516000011 |
---|---|
DIST-CO-RTE-PM | 05-MON-68-1.1/L4.3 |
Award Date | 10/26/2021 |
Closeout Date | 12/14/2023 |
Work Description | PLACE HMA AND MODIFY SIGNAL AND LIGHTING SYSTEMS. |
Location Description | MONTEREY COUNTY IN AND NEAR PACIFIC GROVE AND MONTEREY FROM FOREST AVENUE TO ROUTE 68/1 SEPARATION |
QA Service Level | 1 (Verified on 10/06/2021) |
Sample Information
Sample Taken Date | 05/19/2022 | Sample Unique Key | 22 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/19/2022 |
Sample type | Department Acceptance | A brief description of the sample | 3/4" HMA Type A |
The quantity of what the sample constitutes | 4 Box's HMA-A | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Jerrod | Last name of sampler or witnessed by | Naval |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Graniterock Aromas Drum Plant | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | 1 |
Sublot number | 16 | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2022-05-19-22
DIME Test ID: 2022-05-19-22-1
Testing Lab: CT D05 - Monterey Construction Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2022-05-20
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Wesley Rider
Date of test: 05/19/2022
Test procedure used?: no data
Mass of HMA Sample prior to ignition: no data
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): 0.97 %
Moisture Content: no data
Temperature Compensation Factor: no data
Test Temperature: no data
Corrected Asphalt Binder Content: 4.79 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/20/2022 ✔