Summary for Test 2022-05-18-14-1

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 211260
DEA: 072159U4
EFIS: 0715000160
DIST-CO-RTE-PM07-LA,ORA-5-0.0/1.5, 44.3/44.4
Award Date05/27/2016
Closeout Date08/01/2023
Work DescriptionCONSTRUCT HOV LANES AND MIX FLOW LANES.
Location DescriptionLOS ANGELES AND ORANGE COUNTIES IN BUENA PARK, LA MIRADA, CERRITOS AND SANTA FE SPRINGS FROM ARTESIA BOULEVARD UNDERCROSSING TO NORTH FORK COYOTE CREEK
QA Service Level1 (Verified on 03/16/2016)

Sample Information

Sample Taken Date05/18/2022 Sample Unique Key14
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/18/2022
Sample typeDepartment Acceptance A brief description of the sampleWashed Concrete Sand
The quantity of what the sample constitutes900 CY JPCP From where was the sample collectedManufacturer
First name of sampler or witnessed byHonesto Last name of sampler or witnessed byCastillo
Title of samplerMREAS Telephone number of sampler12134537563
Laboratory sample identification21C-2022 Linked DIME Sample ID
The fabricator/manufacturer/facility nameSECURITY PAVING PORTABLE PLANT- LA MIRADA Transportation Laboratory (TL) NumberC-006593
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0025
The fabricator's/manufacturer's product name for the samplePCC mix The fabricator/manufacturer designation for the sampleMix G3-19-PCC-001
The plant numberLa Mirada A detailed description of where the material sample was collectedBelt Cut at Plant
Where the material sample would have been placed if not sampledJPCP Primary Aggregate Nominal Sizefine
The concrete mix design numberG3-19-PCC-001 Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2022-05-18-14
DIME Test ID: 2022-05-18-14-1
Testing Lab: CT D07 - Plant Services
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2022-06-01

Test Results


What size aggregate is being tested?: Fine Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Honesto Castillo
Date of test: 05/18/2022
Cumulative percent passing the 3/8 in. sieve: 100 %
Cumulative percent passing the #4 sieve: 96 %
Cumulative percent passing the #8 sieve: 81 %
Cumulative percent passing the #16 sieve: 67 %
Cumulative percent passing the #30 sieve: 44 %
Cumulative percent passing the #50 sieve: 21 %
Cumulative percent passing the #100 sieve: 5 %
Cumulative percent passing the #200 sieve: 1 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/1/2022