Summary for Test 2022-02-14-57-4

Test performed: AASHTO T209-12

Project Information

Project IdentifiersProject ID: 214572
DEA: 034E62U4
EFIS: 0319000068
DIST-CO-RTE-PM03-ED-50-18.5/24.2
Award Date05/04/2020
Closeout Date07/15/2025
Work DescriptionCONSTRUCT UC, MED BARRIER, DRAINAGE SYSTEMS & HMA OVERLAY.
Location DescriptionEL DORADO COUNTY IN AND NEAR PLACERVILLE FROM MOSQUITO ROAD UNDERCROSSING TO SCHNELL SCHOOL ROAD UNDERCROSSING AND FROM 0.2 MILE WEST OF STILL MEADOW ROAD TO 0.2 MILE EAST OF CARSON ROAD
QA Service Level1 (Verified on 03/18/2020)

Sample Information

Sample Taken Date02/14/2022 Sample Unique Key57
Date that the sample was received by the laboratory/organization performing the testing03/11/2022 Sample typeVerification
A brief description of the sample3/4" HMA-A The quantity of what the sample constitutes24 boxes of mix
From where was the sample collectedSupplier First name of sampler or witnessed byMike
Last name of sampler or witnessed byO'Halloron Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameTeichert Grantline
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix NumberNot set
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2022-02-14-57
DIME Test ID: 2022-02-14-57-4
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2022-05-16

Test Results


Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Calculated
Tester's full name: Julian Gonzales
Date of test: 03/16/2022
Specific Gravity for Sample 1: 2.544
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters): JMF22-006

Test was verified on 5/16/2022 ✔