Summary for Test 2022-04-29-22-2

Test performed: ASTM C39-10

Project Information

Project IdentifiersProject ID: 215188
DEA: 080F5434
EFIS: 0817000239
Permit Numbers: 0823NMC0369
DIST-CO-RTE-PM08-RIV-I-15,SR-91-6.1-7.6
Award Date03/11/2020
Closeout Date06/05/2024
Work DescriptionI-15 ELC: 15/91 Express Lanes Connector Project (ELC)
Location DescriptionJunction of I-15 and SR-91 in Corona, CA
QA Service Level1 (Verified on 09/16/2020)

Sample Information

Sample Taken Date04/29/2022 Sample Unique Key22
Date that the sample was received by the laboratory/organization performing the testing04/30/2022 Sample typeQuality Assurance
A brief description of the sampleCONCRETE CYLINDERS The quantity of what the sample constitutes6
From where was the sample collectedJob Site First name of sampler or witnessed byFernando
Last name of sampler or witnessed byGarcia Title of samplerQA Inspector Alta vista
Telephone number of sampler Laboratory sample identification1026-430
Linked DIME Sample ID2022-04-29-22 The fabricator/manufacturer/facility nameMyers - Rados Joint Venture
Transportation Laboratory (TL) Number1 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number1419984
The truck number from where the sample was collectedNA10067810 The batch plant ticket number from where the sample was collected30214070
Concrete batch plantMyers Rados JV The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedEB91 NE15conn Sta 429.20 to 412.50 Where the material sample would have been placed if not sampledEB91 NE15 conn Lane and Gore
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2022-04-29-22
DIME Test ID: 2022-04-29-22-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2022-05-10

Test Results


Unit system used?: US Units
Number of specimens: 6
Test performed: With no density determined
Input Type: Measured
Tester's full name: Jose Guzman
Date of test: 05/06/2022
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 5.99 in
Average diameter of cylinder 2: 5.98 in
Average diameter of cylinder 3: 6.01 in
Average diameter of cylinder 4: 6.00 in
Average diameter of cylinder 5: 5.99 in
Average diameter of cylinder 6: 5.99 in
Maximum load on cylinder 1: 58320 lb
Maximum load on cylinder 2: 59320 lb
Maximum load on cylinder 3: 59530 lb
Maximum load on cylinder 4: 60080 lb
Maximum load on cylinder 5: 57320 lb
Maximum load on cylinder 6: 58790 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 3
Type of fracture pattern of cylinder 4: 2
Type of fracture pattern of cylinder 5: 1
Type of fracture pattern of cylinder 6: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Correction factor for cylinder 4: 1.00
Correction factor for cylinder 5: 1.00
Correction factor for cylinder 6: 1.00
Age of specimen: 7 days
Cross sectional area of cylinder 1: 28.18 in^2
Cross sectional area of cylinder 2: 28.09 in^2
Cross sectional area of cylinder 3: 28.37 in^2
Cross sectional area of cylinder 4: 28.27 in^2
Cross sectional area of cylinder 5: 28.18 in^2
Cross sectional area of cylinder 6: 28.18 in^2
Compressive strength of cylinder 1: 2069.6 psi
Compressive strength of cylinder 2: 2111.8 psi
Compressive strength of cylinder 3: 2098.3 psi
Compressive strength of cylinder 4: 2125.2 psi
Compressive strength of cylinder 5: 2034.1 psi
Compressive strength of cylinder 6: 2086.2 psi
Compressive strength (to nearest 10 psi): 2090 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/10/2022 ✔