Summary for Test 2022-05-06-12-2
Test performed: AASHTO T301-13Project Information
| Project Identifiers | Project ID: 55555 DEA: AMRL EFIS: AMRL |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for AASHTO Materials Reference Laboratory (AMRL). |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 05/06/2022 | Sample Unique Key | 12 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 05/06/2022 | Sample type | Proficiency |
| A brief description of the sample | PG64-22 267(A) 268(B) | The quantity of what the sample constitutes | 1 cans FOR 267(A) |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | AASHTO resource |
| Last name of sampler or witnessed by | AASHTO resource | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | AASHTO resource PSP | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 64-28 |
|---|---|---|---|
| Modified | No | Lot number | |
| Sublot number | Tank number | ||
| Time of sample | HMA Supplier | 267(A) | |
| Certified Asphalt Supplier | AASHTO Resource - Frederick MD | Multigrade | No |
| Multigrade Type | Asphalt Binder Mix Number | Not set | |
| HMA Type | Not set | HMA Supplier Mix ID Number | Not set |
Test Details
DIME Sample ID: 2022-05-06-12
DIME Test ID: 2022-05-06-12-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T301-13: Standard Method of Test for Elastic Recovery Test of Asphalt Materials by Means of a Ductilometer
Test Release Date: 2022-05-06
Test Results
Input Type: Measured
Tester's full name: Juan Gomez
Date of test: 05/06/2022
Final Reading from the testing machine (X): 20 cm
% Elongation Recovery: 0 %
General comments (publicly viewable) (Max 1000 characters): ER
Test was verified on 5/6/2022 ✔