Summary for Test 2022-04-30-28-3
Test performed: ASTM D5329-16Project Information
| Project Identifiers | Project ID: 214848 DEA: 081H3414 EFIS: 0818000172 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-210,215,259-Various |
| Award Date | 05/07/2020 |
| Closeout Date | 10/13/2022 |
| Work Description | PLACE RHMA-G, COLD PLANE AC AND REPLACE AC SURFACING. |
| Location Description | SAN BERNARDINO COUNTY ON ROUTE 210, 215 AND 259 AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 07/20/2020) |
Sample Information
| Sample Taken Date | 04/30/2022 | Sample Unique Key | 28 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 05/03/2022 | Sample type | Department Acceptance |
| A brief description of the sample | Asphalt Rubber Binder | The quantity of what the sample constitutes | 1 Quart Can |
| From where was the sample collected | Supplier | First name of sampler or witnessed by | Larry |
| Last name of sampler or witnessed by | TE | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | 0265-22 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | AAA-Corona | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | |
|---|---|---|---|
| Performance Grade | PG 64-16 | Lot number | |
| Sublot number | Asphalt Rubber Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2022-04-30-28
DIME Test ID: 2022-04-30-28-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2022-05-17
Test Results
Input Type: Measured
Tester's full name: Sm Ali
Date of test: 05/06/2022
Temperature: 25 C
Ball Penetration (P1): 0 mm
Final Dial reading (F1): 69 mm
Ball Penetration (P2): 0 mm
Final Dial reading (F2): 71 mm
Ball Penetration (P3): 0 mm
Final Dial reading (F3): 70 mm
Resilience 1: 31 %
Resilience 2: 29 %
Resilience 3: 30 %
Average Resilience: 30 %
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/17/2022 ✔