Summary for Test 2022-04-12-30-1

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 993122
DEA: 07322304
EFIS: 0716000054
DIST-CO-RTE-PM07-LA-110-22.8
Award Date10/04/2021
Closeout Date09/24/2024
Work DescriptionCONSTRUCT AND REPLACE BRIDGE RAILS.
Location DescriptionLOS ANGELES COUNTY IN LOS ANGELES AT FIFTH STREET OVERCROSSING AND AT SIXTH STREET OVERCROSSING
QA Service Level1 (Verified on 08/04/2021)

Sample Information

Sample Taken Date04/12/2022 Sample Unique Key30
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing04/14/2022
Sample typeDepartment Acceptance A brief description of the sample1" Max PCC Aggregate
The quantity of what the sample constitutes56 CY From where was the sample collectedManufacturer
First name of sampler or witnessed byHonesto Last name of sampler or witnessed byCastillo
Title of samplerMREAS Telephone number of sampler12134537563
Laboratory sample identification6249, 6250, 6251 Linked DIME Sample ID
The fabricator/manufacturer/facility nameNational Ready Mix Concrete-Vernon Transportation Laboratory (TL) NumberC-006570 C-006571 C-006572
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0052
The fabricator's/manufacturer's product name for the samplePCC mix The fabricator/manufacturer designation for the sampleS62578
The plant numberVernon A detailed description of where the material sample was collectedBelt Cut at Plant
Where the material sample would have been placed if not sampledBarrier Rails Primary Aggregate Nominal Size1 inch
The concrete mix design numberS62578 Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2022-04-12-30
DIME Test ID: 2022-04-12-30-1
Testing Lab: CT D07 - Plant Services
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2022-05-04

Test Results


What size aggregate is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: D. Padilla
Date of test: 04/18/2022
Sieve SizeCumulative Percent Passing
100 %
100 %
100 %
100 %
99 %
92 %
75 %
59 %
48 %
37 %
25 %
15 %
6 %
2 %
1 %
General comments (publicly viewable) (Max 1000 characters): This Gradation is the Combined Grading of SRL Lab #6249; 6250 & 6251

Test was verified on 5/4/2022