Summary for Test 2022-04-21-25-2
Test performed: AASHTO T240-17Project Information
| Project Identifiers | Project ID: 214848 DEA: 081H3414 EFIS: 0818000172 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-210,215,259-Various |
| Award Date | 05/07/2020 |
| Closeout Date | 10/13/2022 |
| Work Description | PLACE RHMA-G, COLD PLANE AC AND REPLACE AC SURFACING. |
| Location Description | SAN BERNARDINO COUNTY ON ROUTE 210, 215 AND 259 AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 07/20/2020) |
Sample Information
| Sample Taken Date | 04/21/2022 | Sample Unique Key | 25 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 04/26/2022 | Sample type | Department Acceptance |
| A brief description of the sample | PG Asphalt Binder | The quantity of what the sample constitutes | 1 Quart Can |
| From where was the sample collected | Supplier | First name of sampler or witnessed by | Victor |
| Last name of sampler or witnessed by | QC | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | 0251-22 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | AAA-Corona | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 64-28 M |
|---|---|---|---|
| Modified | Yes | Lot number | |
| Sublot number | Tank number | ||
| Time of sample | HMA Supplier | ||
| Certified Asphalt Supplier | San Joaquin Refinery - Bakersfield CA | Multigrade | No |
| Multigrade Type | Asphalt Binder Mix Number | Not set | |
| HMA Type | Not set | HMA Supplier Mix ID Number | Not set |
Test Details
DIME Sample ID: 2022-04-21-25
DIME Test ID: 2022-04-21-25-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2022-05-04
Test Results
Is mass change based on one or two containers?: Two
Input Type: Measured
Tester's full name: Majid Essa
Date of test: 05/02/2022
Any material loss from containers during heating process/testing?: Yes
Mass of empty container #1: 172.983 grams
Mass of empty container #2: 167.916 grams
Mass of container #1 before test (m1i): 208.107 grams
Mass of container #2 before test (m2i): 202.744 grams
Mass of container #1 after test (m1f): 208.091 grams
Mass of container #2 after test (m2f): 202.731 grams
Average mass change: -0.041 percent
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/4/2022 ✔